Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J. optom. (Internet) ; 15(3): 1-9, Jul-Sep.2022. tab, graf
Artigo em Inglês | IBECS | ID: ibc-204706

RESUMO

Purpose: To assess visual results (including the Lapid-Kushlin defocus coefficient), and satisfaction, following the implantation of PanOptix® a trifocal intraocular lens.Methods: Observational, retrospective cohort study. 130 eyes of 65 subjects with bilateral implantation were included. Binocular uncorrected visual acuities [distance (Binocular UDVA), intermediate (Binocular UIVA) and near (Binocular UNVA)] were measured. Also, the manifest refraction, binocular defocus curve and binocular contrast sensitivity were determined. The Lapid-Kushlin defocus coefficient, a new single numerical parameter based on the area under the curve of the defocus curve, was calculated. The validated Spanish CATQUEST-9SF satisfaction survey was applied.Results: Postoperative visual acuity ranges were: binocular UDVA 0.18 to 0.0 LogMAR, binocular UIVA 0.30 to 0.0 LogMAR and Binocular UNVA 0.18 to 0.0 LogMAR. The levels of contrast sensitivity both in bright light conditions (with and without glare) and low light conditions with glare, remained within the limits of normality. Under scotopic conditions without glare values below normality were found at lower spatial frequencies. The binocular defocus curve showed a plateau without a clearly evident peak. The Lapid-Kushlin defocus coefficient was 0.199. Two patients (3.1%) needed glasses after the procedure for near and intermediate vision. No patient manifested great visual difficulties or was dissatisfied with the results.Conclusions: The trifocal platform showed very good results in this series of patients. 96.9% of the patients achieved independence of the glasses and expressed a high degree of satisfaction. The Lapid-Kushlin defocus coefficient was better than those calculated from literature, for other multifocal intraocular lenses. (AU)


Assuntos
Humanos , Catarata/terapia , Lentes Intraoculares Multifocais , Satisfação do Paciente , Satisfação Pessoal , Desenho de Prótese , Refração Ocular , Estudos Retrospectivos
2.
J Optom ; 15(3): 219-227, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34674967

RESUMO

PURPOSE: To assess visual results (including the Lapid-Kushlin defocus coefficient), and satisfaction, following the implantation of PanOptix® a trifocal intraocular lens. METHODS: Observational, retrospective cohort study. 130 eyes of 65 subjects with bilateral implantation were included. Binocular uncorrected visual acuities [distance (Binocular UDVA), intermediate (Binocular UIVA) and near (Binocular UNVA)] were measured. Also, the manifest refraction, binocular defocus curve and binocular contrast sensitivity were determined. The Lapid-Kushlin defocus coefficient, a new single numerical parameter based on the area under the curve of the defocus curve, was calculated. The validated Spanish CATQUEST-9SF satisfaction survey was applied. RESULTS: Postoperative visual acuity ranges were: binocular UDVA 0.18 to 0.0 LogMAR, binocular UIVA 0.30 to 0.0 LogMAR and Binocular UNVA 0.18 to 0.0 LogMAR. The levels of contrast sensitivity both in bright light conditions (with and without glare) and low light conditions with glare, remained within the limits of normality. Under scotopic conditions without glare values below normality were found at lower spatial frequencies. The binocular defocus curve showed a plateau without a clearly evident peak. The Lapid-Kushlin defocus coefficient was 0.199. Two patients (3.1%) needed glasses after the procedure for near and intermediate vision. No patient manifested great visual difficulties or was dissatisfied with the results. CONCLUSIONS: The trifocal platform showed very good results in this series of patients. 96.9% of the patients achieved independence of the glasses and expressed a high degree of satisfaction. The Lapid-Kushlin defocus coefficient was better than those calculated from literature, for other multifocal intraocular lenses.


Assuntos
Catarata , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Satisfação do Paciente , Satisfação Pessoal , Estudos Prospectivos , Desenho de Prótese , Refração Ocular , Estudos Retrospectivos , Visão Binocular
3.
Curr Eye Res ; 46(5): 672-677, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32966108

RESUMO

PURPOSE/AIM: To assess, following the standards, the results of safety, efficacy and predictability for a trifocal intraocular lens and to evaluate contrast sensitivity and visual acuity defocus curve. MATERIALS AND METHODS: Fifty subjects operated on cataract surgery or refractive lens exchange with a trifocal intraocular lens have been recruited for the study. The monocular uncorrected visual acuity (VA) at far, intermediate (67 cm) and near (40 cm) distances in addition to corrected VA at far and near distances was evaluated at 1 week, 1 month and 3 months after surgery. Postoperative refraction, binocular contrast sensitivity function (CSF) and binocular defocus curves were also collected at the 3-month follow-up visit. RESULTS: Mean uncorrected VA was 0.10, 0.07 and 0.05 logMAR at far, intermediate and near distances. Corrected distance VA at far and near distances was 0.04 and 0.02 logMAR. Ninety percent and 100% achieved a spherical equivalent in ±0.50 D and ±1.00 D, respectively. CSF was above normal range for 12 and 18 cycles per degree (cpd) in all the conditions, inside the normal range in 1.5, 3 and 6 cpd and only decreased below normal range for 1.5 and 3 cpd in mesopic vision without glare. CONCLUSIONS: The procedure achieved a safety, efficacy and predictability similar to those reported by previous studies. The CSF was generally enhanced after the procedure in comparison to those reported in non-operated subjects above 60 years old. Previous studies might underestimate the effective distance of the intermediate and near foci.


Assuntos
Sensibilidades de Contraste/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Facoemulsificação , Pseudofacia/fisiopatologia , Aberrometria , Idoso , Contagem de Células , Topografia da Córnea , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Tomografia de Coerência Óptica , Visão Binocular/fisiologia , Acuidade Visual/fisiologia
4.
Clin Ophthalmol ; 13: 311-324, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30809088

RESUMO

This project was aimed at achieving consensus on the management of astigmatism during cataract surgery by ophthalmologists from Latin America using modified Delphi technique. Relevant peer-reviewed literature was identified, and 21 clinical research questions associated with the definition, classification, measurement, and treatment of astigmatism during cataract surgery were formulated. Twenty participants were divided into seven groups, and each group was assigned three questions to which they had to respond in written form, after thoroughly reviewing the literature. The assigned questions with corresponding responses by each group were discussed with other participants in round 4 - presentation of findings. The consensus was achieved if approval was obtained from at least 80% of participants. The present paper provides several agreements and recommendations for management of astigmatism during cataract surgery, which could potentially minimize the variability in practice patterns and help ophthalmologists adopt optimal practices for cataract patients with astigmatism and improve patient satisfaction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...